Description
FLEXmax 80 MPPT is a solar charge controller that can adapt to changing climate. FLEXmax MPPT is suitable for 12V, 24V, 36V, 48V and 60V solar systems,the ability to “step-down” a higher PV voltage to charge batteries of a lower voltage, and an innovative MPPT software algorithm that increases your PV array’s power yield by up to 30%
The maximum charging current is 60A and 80A. FM MPPT has a built-in cooling fan,Thanks to active cooling and intelligent thermal management cooling, both FLEXmax charge controllers can operate at their full maximum current rating, 60 Amps or 80 Amps respectively, in ambient temperatures as high as 40℃.
It has a four-row LCD display that displays various states and faults, and is easy to program its many operating parameters. Record the last 128 days of operation data (ampere-hours, watt-hours, floating time, peak watts, amperes, solar array voltage, maximum cell voltage, minimum cell voltage and absorption time, cumulative ampere-hours, production KWH) for review.
Flexmax60 MPPT | Flexmax80 MPPT | |
Nominal Battery Voltages | 12,24,36,48,or 60 VDC(Single model-selectable via field programming at start-up) | 12,24,36,48,or 60 VDC(Single model-selectable via field programming at start-up) |
Maximum Output Current | 60 amps@104°F(40°℃)with adjustable current limit | 80amps@104°F(40℃)with adjustable current limit |
Maximum Solar Array STC Nameplate | 12 VDC systems 900 Watts/24 VDC systems 1800 Watts 48 VDC systems 3600 Watts/60 VDC Systems 4500 Watts |
12 VDC systems 1250 Watts/24 VDC systems 2500 Watts 48 VDC systems 5000 Watts /60 VDC Systems 7500 Watts |
NEC Recommended Solar Array STC Nameplate | 12 VDC systems 750 Watts /24 VDC systems 1500 Watts 48 VDC systems 3000 Watts/60 VDC Systems 3750 Watts |
12 VDC systems 1000 Watts /24 VDC systems 2000 Watts 48 VDC systems 4000 Watts/60 VDC Systems 5000 Watts |
PV Open Circuit Voltage(VOC) | 150 VDC absolute maximum coldest conditions/145 VDC start-up and operating maximum | 150 VDC absolute maximum coldest conditions/145 VDC start-up and operating maximum |
Standby Power Consumption | Less than 1 Watt typical | Less than 1 Watt typical |
Power Conversion Efficiency | 98.1%@60Amps in at 48 VDC System voltage-Typical | 97.5%@80Amps in at 48 VDC System voltage-Typical |
Charging Regulation | Five Stages:Bulk, Absorption, Float, Silent and Equalization | Five Stages: Bulk,Absorption, Float, Silent and Equalization |
Voltage Regulation Set points | 10 to 80 VDC user adjustable with password protection | 10 to 80 VDC user adjustable with password protection |
Equalization Charging | Programmable Voltage Setpoint and Duration -Automatic Termination when completed | Programmable Voltage Setpoint and Duration -Automatic Termination when completed |
Battery Temperature Compensation | Automatic with optional RTS installed/5.0 mV per°C per 2V battery cell | Automatic with optional RTS installed/5.0 mV perC per 2V battery c |
Voltage Step-Down Capability | Can charge a lower voltage battery from a higher voltage PV array -Max 150 VDC input | Can charge a lower voltage battery from a higher voltage PV array -Max 150 VDC input |
Programmable Auxilary Control Output | 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) | 12 VDC output signal which can be programmed for diferent control applications (Maximum of 0.2 amps DC) |
Status Display | 3.1″(8 cm) backlit LCD screen-4 lines with 80 alphanumeric characters total | 3.1″(8 cm) backlit LCD screen-4 lines with 80 alphanumeric characte total |
Remote Display and Controller | Optional Mate or Mate2 with RS232 Serial Communications Port | Optional Mate or Mate2 with RS232 Serial Communications Port |
Network Cabeling | Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) | Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) |
Data Logging | Last 128 days of Operation -Amp Hours, Watt Hours, Time in Float,Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours,and kW Hours of production |
Last 128 days of Operation -Amp Hours, Watt Hours, Time in Float,Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours,and kW Hours of production |
Hydro Turbine Applications | Consult factory for approved Turbines | Consult factory for approved Turbines |
Positive Ground Applications | Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) |
Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) |
Operating Temperature Range | Minimum -40°to maximum 60°C(Power capacity of the controller is automatically derated when operated above 40°C) | Minimum -40°to maximum 60°C(Power capacity of the controller is automatically derated when operated above 40°C) |
Environmental Rating | Indoor Type 1 | Indoor Type 1 |
Conduit Knockouts | One 1″(35mm)on the back; One 1″(35mm)on the left side; Two 1″(35mm)on the bottom | One 1″(35mm)on the back; One 1″(35mm)on the left side; Two 1″(35mm)on the bottom |
Weight -Unit | 5.3 kg | 5.6 kg |
-Shipping | 6 kg | 6.3 kg |
Dimensions – Unit | 40×14×10 cm | 44×14×10 cm |
-Shipping | 46×30×20 cm | 51×24×21.5 cm |
Options | Remote Temperature Sensor(RTS), HUB 4,HUB 10,MATE,MATE 2 | Remote Temperature Sensor(RTS), HUB 4,HUB 10, MATE, MATE 2 |
Menu Languages | English & Spanish | English & Spanish |
Application
Home Off-Grid & Back-Up Power Solutions
FAQs:
Our FLEXmax MPPT 60A and 80A start offer in 2013 , till now still hot sale. We improved the quality constantly in the first 5 years even the packing box according to our customers required. And we are assured our quality is perfect. we tested the goods before shipping . Almost the faulty is from the end user wrongly operate.For example , the recent faulty, our FM design MPPT Solar charge controller can be connected in paraller max 2 pcs and must be with the accessories MATE3S and HuB4 or HUB 10 together working. But some customer connected 3 pcs in paraller without those accessories. That’s the problem. The video can help us understand the problem better than only the word.We just want to the solvement quick.Thank you for your kindly understanding
The Bolanmu Battery Charger/Inverter series is a true energy manager, unique and compact, that has 5 main functions. It can be an off-grid inverter, battery charger, current injector, transfer system and provide support to an AC source.
Reviews
There are no reviews yet.