AJ Hybrid Inverter is the latest development of Bolanmu Energy products, AJ Hybrid Inverter has begun mass production, The AJ Hybrid consists of sine wave inverters that convert battery voltage into utility quality AC voltage which can be used with all usual electrical appliances, but also optional PWM Solar regulator, Delivered with battery and AC cables it is a true plug and forget solution.
AJ series Hybrid produced by Bomulan Energy has a total of 4 models, namely AJ2100-12, AJ500-12,AJ600-24 and AJ700-48, which support 12V, 24V and 48V Battery BANK. Detailed data can be found in the following parameter table:
Technical data | |||||
Inverter | |||||
Nominal battery voltage | 12Vdc | 24Vdc | 48 Vdc | 12 Vdc | |
Input voltage range | 10.5-16Vdc | 21-32Vdc | 42-64Vdc | 10.5-16Vdc | |
Continuous power@25℃ | 400 VA | 500 VA | 500 VA | 2000 VA | |
Power 30 min.@ 25℃ | 500 VA | 600 VA | 700 VA | 2100 VA | |
Power 5 min.@ 25℃ | 575 VA | 675 VA | 900VA | 2450 VA | |
Power 5 sec.@ 25℃ | 1000VA | 1200 VA | 1400 VA | 5000 VA | |
Asymmetric load | 250 VA | 300 VA | 300VA | 1000 VA | |
Max.efficiency(%) | 93 % | 94 % | 94% | 92 % | |
Cos j max. | 0.1-1up to 400 VA | 0.1-1up to 500 VA | 0.1-1up to 500VA | 0.1-1up to 2000VA | |
Detection of the load | Adjustable: 1 to 20W | ||||
Short-circuit current AC 2 sec. | 5.2 Aac(10.4 Aac*) | 5.7 Aac(11.4 Aac*) | 7 Aac(14Aac*) | 26 Aac(52Aac*) | |
Output voltage | Sine wave 230 Vac(120Vac*)±5 % | ||||
Frequency | 50Hz(60Hz*)±0.05%(crystal controlled) | ||||
Distortion THD (resistive load) | <3%(@Pnom&Uinnom.) | ||||
Consumption Stand-by | 0.4 W | 0.6 W | 1.5 W | 0.7W | |
Consumption “ON”no load | 4.6 W | 7.2 W | 12W | 16W | |
Overheat protection(±5℃) | Shut down@75℃-Auto-restart@70℃ | ||||
Overload and short circuit protection | Automatic disconnection with 2 time restart attempt | ||||
Reverse polarity protection as intemal fuse | 120 A | 90 A | 60 A | Not protected | |
Deep discharge battery protection | Shut [email protected]×Uom-Automatic restart@Unom | ||||
Max. battery voltage | Shut off@>1.33×Unom-Automatic restart@<Umax | ||||
Acoustic alarm | Before low battery or overheating disconnection | ||||
General data | |||||
Weight | 4.5 kg | 19KG | |||
Dimension h/w/l[mm] | 142/240/84 | 273/399/117 | |||
Protection index IP | IP 30 conforms to DIN 40050 | ||||
Certification ECE-R 10 (E24) | √ | √ | × | √ | |
Conformity | Low Voltage Directive (LVD) 2014/35/EU: EN/IEC 62109-1, 62109-2, 62477-1 | ||||
Operating temperature | -20℃ to +50℃ | ||||
Relative humidity in operation | 95 % without condensation | ||||
Ventilation forced | From 45℃±5℃ | ||||
Acoustic level | <45 dB(with ventilation) | ||||
Approximate correction of Pnom | -1.5%/℃ from +25℃ | ||||
Recommended battery capacity | >5×Pnom/Unom(recommended value in Ah) | ||||
Length cables(Battery/AC out) | 1.5m/1 m | 1.7m/1 m | |||
Options | |||||
Solar regulator | Voltage max. | 25 Vdc | 45 Vdc | 90 Vdc | 25 Vdc |
Current max. | 15 Adc | 30 Adc | |||
Principle | Floating 3 stages (I/U/UO) | ||||
Absorption voltage | 14.4Vdc | 28.8Vdc | 57.6Vdc | 14.4Vdc | |
Floating voltage | 13.6Vdc | 27.2Vdc | 54.4Vdc | 13.6Vdc | |
Remote control (RCM-01/-02/-03) | √ | √ | √ | √ |
As a professional solar equipment manufacturer, Bolanmu Energy has been developing and producing solar controllers and inverters for more than 10 years. Among them, our FlexmaxMPPT is sold well in the world. There are also classic XTS Hybrid inverter/charger,XTM Hybrid inverter/charger, XTH Hybrid inverter/charger, we believe that our latest research and development production AJ hybrid The inverter also can provide customers with a quality experience!