Description
AJ 600-24-S
The AJ 600-24-s series pure sine wave inverters convert battery voltage into high-quality 230/120Vac which can be used for all electrical appliances.Designed to meet industrial and domestic needs the AJ is the optimal solution for stand-alone applications fulfilling the highest requirements in terms of comfort,safety and reliability.Manufactured in China with a 5-year warranty and delivered with AC-and battery cables,the AJ it is a true “plug and forget solution”.
Reliable and compact for your small to medium sized system
- High and steady efficiency
- Outstanding overload capabilities
- Digital regulation and control by microprocessor
- Electrical supply to any type of appliance
- Full internal protection
- Battery lifetime optimization(B.L.O.)function
- Plug&Play,suplied with battery and AC cables
Optional built-in solar regulator
- Optional integrated PWM solar charge controller with 3 stages (I/U/UO)
Accessory
- Remote control (JT8)enables the control (ON/OFF) and the status display(On,Standby, Temporary Off)
Technical data | AJ500-12-S | AJ 600-24-S | AJ 700-48-S | AJ 2100-12-S | |
Inverter | |||||
Nominal battery voltage | 12Vdc | 24Vdc | 48 Vdc | 12 Vdc | |
Input voltage range | 10.5-16Vdc | 21-32Vdc | 42-64Vdc | 10.5-16Vdc | |
Continuous power@25℃ | 400 VA | 500 VA | 500 VA | 2000 VA | |
Power 30 min.@ 25℃ | 500 VA | 600 VA | 700 VA | 2100 VA | |
Power 5 min.@ 25℃ | 575 VA | 675 VA | 900VA | 2450 VA | |
Power 5 sec.@ 25℃ | 1000VA | 1200 VA | 1400 VA | 5000 VA | |
Asymmetric load | 250 VA | 300 VA | 300VA | 1000 VA | |
Max.efficiency(%) | 93 % | 94 % | 94% | 92 % | |
Cos j max. | 0.1-1up to 400 VA | 0.1-1up to 500 VA | 0.1-1up to 500VA | 0.1-1up to 2000VA | |
Detection of the load | Adjustable: 1 to 20W | ||||
Short-circuit current AC 2 sec. | 5.2 Aac(10.4 Aac*) | 5.7 Aac(11.4 Aac*) | 7 Aac(14Aac*) | 26 Aac(52Aac*) | |
Output voltage | Sine wave 230 Vac(120Vac*)±5 % | ||||
Frequency | 50Hz(60Hz*)±0.05%(crystal controlled) | ||||
Distortion THD (resistive load) | <3%(@Pnom&Uinnom.) | ||||
Consumption Stand-by | 0.4 W | 0.6 W | 1.5 W | 0.7W | |
Consumption “ON”no load | 4.6 W | 7.2 W | 12W | 16W | |
Overheat protection(±5℃) | Shut down@75℃-Auto-restart@70℃ | ||||
Overload and short circuit protection | Automatic disconnection with 2 time restart attempt | ||||
Reverse polarity protection as intemal fuse | 120 A | 90 A | 60 A | Not protected | |
Deep discharge battery protection | Shut [email protected]×Uom-Automatic restart@Unom | ||||
Max. battery voltage | Shut off@>1.33×Unom-Automatic restart@<Umax | ||||
Acoustic alarm | Before low battery or overheating disconnection | ||||
General data | |||||
Weight | 4.5 kg | 19KG | |||
Dimension h/w/l[mm] | 142/240/84 | 273/399/117 | |||
Protection index IP | IP 30 conforms to DIN 40050 | ||||
Certification ECE-R 10 (E24) | √ | √ | × | √ | |
Conformity | Low Voltage Directive (LVD) 2014/35/EU: EN/IEC 62109-1, 62109-2, 62477-1 Electromagnetic Compliance (EMC) Directive 2014/30/EU: EN/IEC 61000-3-3, 61000-6-2, 61000-6-4, 62040-2 |
||||
Operating temperature | -20℃ to +50℃ | ||||
Relative humidity in operation | 95 % without condensation | ||||
Ventilation forced | From 45℃±5℃ | ||||
Acoustic level | <45 dB(with ventilation) | ||||
Approximate correction of Pnom | -1.5%/℃ from +25℃ | ||||
Recommended battery capacity | >5×Pnom/Unom(recommended value in Ah) | ||||
Length cables(Battery/AC out) | 1.5m/1 m | 1.7m/1 m | |||
Options | |||||
Solar regulator | Voltage max. | 25 Vdc | 45 Vdc | 90 Vdc | 25 Vdc |
Current max. | 15 Adc | 30 Adc | |||
Principle | Floating 3 stages (I/U/UO) | ||||
Absorption voltage | 14.4Vdc | 28.8Vdc | 57.6Vdc | 14.4Vdc | |
Floating voltage | 13.6Vdc | 27.2Vdc | 54.4Vdc | 13.6Vdc | |
Remote control (RCM-01/-02/-03) | √ | √ | √ | √ |
Application
Home Off-Grid & Back-Up Power Solutions
Reviews
There are no reviews yet.